{"id":19371,"date":"2023-11-10T08:10:00","date_gmt":"2023-11-10T07:10:00","guid":{"rendered":"https:\/\/www.ntnu.no\/blogger\/cius\/?p=19371"},"modified":"2023-11-09T15:13:08","modified_gmt":"2023-11-09T14:13:08","slug":"higher-resolution-with-new-ultrasound-probe-design","status":"publish","type":"post","link":"https:\/\/www.ntnu.no\/blogger\/cius\/2023\/higher-resolution-with-new-ultrasound-probe-design\/","title":{"rendered":"Higher resolution with new ultrasound probe design"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">Commercial ultrasound probe designs have their pros and cons, but what if we combine the pros of two designs to create a new type of transducer? One that can acquire more information and producer higher resolution images for improved cardiovascular diagnosis?<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">This is what I am working on in my PhD at USN with CIUS partners GE Vingmed Ultrasound (Horten, Norway) and GE Parallel Design (Nice France). What we have come up with is the DHUT, by combining piezoelectric transducers with capacitive micromachined ultrasound transducers (CMUTs).<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"474\" src=\"https:\/\/www.ntnu.no\/blogger\/cius\/wp-content\/uploads\/sites\/79\/2023\/11\/DHUT_properties_Duy-1024x474.png\" alt=\"Graphic showing how ultrasound imaging quality is affected by harmonic imaging, signal processing and wideband transducers\" class=\"wp-image-19377\" srcset=\"https:\/\/www.ntnu.no\/blogger\/cius\/wp-content\/uploads\/sites\/79\/2023\/11\/DHUT_properties_Duy-1024x474.png 1024w, https:\/\/www.ntnu.no\/blogger\/cius\/wp-content\/uploads\/sites\/79\/2023\/11\/DHUT_properties_Duy-300x139.png 300w, https:\/\/www.ntnu.no\/blogger\/cius\/wp-content\/uploads\/sites\/79\/2023\/11\/DHUT_properties_Duy-768x355.png 768w, https:\/\/www.ntnu.no\/blogger\/cius\/wp-content\/uploads\/sites\/79\/2023\/11\/DHUT_properties_Duy-1536x711.png 1536w, https:\/\/www.ntnu.no\/blogger\/cius\/wp-content\/uploads\/sites\/79\/2023\/11\/DHUT_properties_Duy-2048x948.png 2048w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><figcaption class=\"wp-element-caption\">Fig. 1 Ultrasound imaging quality is affected by three main factors: application of harmonic imaging, wideband transducers and signal processing. The DHUT project focuses on the design of wideband transducers. The broader the bandwidth of transducers, the higher the resultant ultrasound image quality.<\/figcaption><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Piezoelectric transducers vs CMUTs<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Conventional ultrasound probes rely on piezoelectric transducers, where the same piezoelectric component functions as both transmitter and receiver for sound waves \u2013 like a combined loudspeaker and microphone. However, the piezoelectric transducers have bandwidth limitations. Furthermore, acoustic properties of piezoelectric materials differ significantly from those of tissues, resulting in ineffective sound transmission between the piezoelectric material and the tissues. To overcome the mismatch in the acoustic properties, it is necessary to employ acoustic matching layers between the piezoelectric layer and the tissues.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">As an alternative to piezoelectric transducers, capacitive micromachined ultrasound transducers (CMUTs) have gained interest because of their potential advantages over the conventional transducers. The CMUTs offer the possibility of broad bandwidth and high sensitivity, and they can be integrated directly with the electronic system. Therefore, CMUTs can create compact sensing devices for ultrasound imaging. The CMUTs are made by standard lithography processes, which can be suitable for mass production at high volume and low cost. Nevertheless, CMUTs possess some drawbacks, such as requiring a high DC bias voltage (some hundreds of volts), low transmit power and inherent nonlinearity.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Best of two worlds &#8211; DHUT<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">We combine a piezoelectric transducer and a CMUT into a single acoustic stack, called a dual frequency hybrid ultrasound transducer \u2013 DHUT. The DHUT uses a piezoelectric material for sending waves and a CMUT for receiving reflected waves. With this unique structure, the DHUT possesses the strong transmit power of the piezoelectric material, and the broad receiving bandwidth of the CMUT. These features make the DHUT promising for improving the quality of ultrasound images.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"246\" height=\"243\" src=\"https:\/\/www.ntnu.no\/blogger\/cius\/wp-content\/uploads\/sites\/79\/2023\/11\/DHUT_structure_with_CMUT_Duy.png\" alt=\"Illustration of how the layers in a DHUT.\" class=\"wp-image-19378\" style=\"width:545px;height:auto\" srcset=\"https:\/\/www.ntnu.no\/blogger\/cius\/wp-content\/uploads\/sites\/79\/2023\/11\/DHUT_structure_with_CMUT_Duy.png 246w, https:\/\/www.ntnu.no\/blogger\/cius\/wp-content\/uploads\/sites\/79\/2023\/11\/DHUT_structure_with_CMUT_Duy-70x70.png 70w\" sizes=\"auto, (max-width: 246px) 100vw, 246px\" \/><figcaption class=\"wp-element-caption\">Fig. 2 DHUT structure with CMUT on the top of a piezoelectric stack, consisting of a matching layer, a piezoelectric material and a de-matching layer. Elements of the array are separated by thin kerfs.<\/figcaption><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">How to make and test DHUTs?<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">A DHUT contains a piezoelectric array and a CMUT, and the fabrication of a DHUT involves simultaneous fabrication of the piezoelectric array and the CMUT array. The piezoelectric array is constructed at USN while the CMUT is produced at Aculab, Roma Tre University, Italy. The piezoelectric arrays are sent to Aculab for lamination with the CMUT.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Several prototypes of the piezoelectric array have been dispatched to Aculab and are presently waiting for CMUT attachment. The completed prototypes will be returned to USN for testing. GE Ultrasound Vingmed are developing an electronic system for integrating the DHUT probe into GE\u2019s ultrasound systems. When finished, this will give us an exciting opportunity to evaluate the imaging capabilities of our new technology, and to compare this with a traditional ultrasound imaging probe.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"513\" height=\"228\" src=\"https:\/\/www.ntnu.no\/blogger\/cius\/wp-content\/uploads\/sites\/79\/2023\/11\/Piezoelectric_array_Duy.png\" alt=\"A piezoelectric array on a flexible circuit\" class=\"wp-image-19379\" srcset=\"https:\/\/www.ntnu.no\/blogger\/cius\/wp-content\/uploads\/sites\/79\/2023\/11\/Piezoelectric_array_Duy.png 513w, https:\/\/www.ntnu.no\/blogger\/cius\/wp-content\/uploads\/sites\/79\/2023\/11\/Piezoelectric_array_Duy-300x133.png 300w\" sizes=\"auto, (max-width: 513px) 100vw, 513px\" \/><figcaption class=\"wp-element-caption\">Fig. 3 A piezoelectric array on a flexible circuit. The active area (black colour at centre) is 11.0 x 16.3 mm<sup>2<\/sup>.<\/figcaption><\/figure>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"449\" height=\"405\" src=\"https:\/\/www.ntnu.no\/blogger\/cius\/wp-content\/uploads\/sites\/79\/2023\/11\/CMUT_die_Duy.jpg\" alt=\"A CMUT die, containing 120x120 element - array. \" class=\"wp-image-19380\" srcset=\"https:\/\/www.ntnu.no\/blogger\/cius\/wp-content\/uploads\/sites\/79\/2023\/11\/CMUT_die_Duy.jpg 449w, https:\/\/www.ntnu.no\/blogger\/cius\/wp-content\/uploads\/sites\/79\/2023\/11\/CMUT_die_Duy-300x271.jpg 300w\" sizes=\"auto, (max-width: 449px) 100vw, 449px\" \/><figcaption class=\"wp-element-caption\">Fig. 4 A CMUT die, containing 120&#215;120 element &#8211; array. The die size is 15.4 x 15.4 mm<sup>2<\/sup>.<\/figcaption><\/figure>\n","protected":false},"excerpt":{"rendered":"<p>Commercial ultrasound probe designs have their pros and cons, but what if we combine the pros of two designs to create a new type of transducer? One that can acquire more information and producer higher resolution images for improved cardiovascular diagnosis?<\/p>\n","protected":false},"author":433,"featured_media":19379,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[2],"tags":[15,228,229,71,224,52,145,24,179],"class_list":["post-19371","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-medical","tag-cardiology","tag-cmut","tag-dhut","tag-echocardiography","tag-ge-vingmed","tag-piezoelectric","tag-transducer","tag-transducer-design","tag-usn"],"_links":{"self":[{"href":"https:\/\/www.ntnu.no\/blogger\/cius\/wp-json\/wp\/v2\/posts\/19371","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.ntnu.no\/blogger\/cius\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.ntnu.no\/blogger\/cius\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.ntnu.no\/blogger\/cius\/wp-json\/wp\/v2\/users\/433"}],"replies":[{"embeddable":true,"href":"https:\/\/www.ntnu.no\/blogger\/cius\/wp-json\/wp\/v2\/comments?post=19371"}],"version-history":[{"count":5,"href":"https:\/\/www.ntnu.no\/blogger\/cius\/wp-json\/wp\/v2\/posts\/19371\/revisions"}],"predecessor-version":[{"id":19381,"href":"https:\/\/www.ntnu.no\/blogger\/cius\/wp-json\/wp\/v2\/posts\/19371\/revisions\/19381"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.ntnu.no\/blogger\/cius\/wp-json\/wp\/v2\/media\/19379"}],"wp:attachment":[{"href":"https:\/\/www.ntnu.no\/blogger\/cius\/wp-json\/wp\/v2\/media?parent=19371"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.ntnu.no\/blogger\/cius\/wp-json\/wp\/v2\/categories?post=19371"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.ntnu.no\/blogger\/cius\/wp-json\/wp\/v2\/tags?post=19371"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}