{"id":15199,"date":"2016-12-16T11:09:28","date_gmt":"2016-12-16T10:09:28","guid":{"rendered":"http:\/\/blog.medisin.ntnu.no\/?p=15199"},"modified":"2021-08-18T14:02:42","modified_gmt":"2021-08-18T12:02:42","slug":"exploiting-nonlinear-distortion-to-switch-from-black-and-white-to-colour-in-underwater-acoustic-imaging","status":"publish","type":"post","link":"https:\/\/www.ntnu.no\/blogger\/cius\/2016\/exploiting-nonlinear-distortion-to-switch-from-black-and-white-to-colour-in-underwater-acoustic-imaging\/","title":{"rendered":"Exploiting nonlinear distortion to switch from black and white to colour in underwater acoustic imaging"},"content":{"rendered":"<p>When ultrasound propagates through water nonlinear effects come into play and distort the signal originally transmitted (Figure 1). The effect of this distortion can be seen as a transfer of energy around what is called \u201charmonic frequencies\u201d. For example if the signal originally transmitted has a frequency of 1 MHz, after nonlinear distortion it will show components around 1 MHz, but also 2 MHz, 3 MHz, etc. (Figure 1).<\/p>\n<p>The component around 1MHz is called the fundamental and those around 2 MHz, 3 MHz, etc. are called second harmonic, third harmonic, etc. A \u201cmonochromatic\u201d signal (we use this term from the optical field to qualify a pure tone with one single frequency) becomes \u201cpolychromatic\u201d. One could say that nonlinear effects \u201cadd colours\u201d to a signal. By &#8220;listening&#8221; around these harmonic frequencies additional information can be extracted.<\/p>\n<figure id=\"attachment_15202\" aria-describedby=\"caption-attachment-15202\" style=\"width: 836px\" class=\"wp-caption alignnone\"><a href=\"https:\/\/www.ntnu.no\/blogger\/cius\/wp-content\/uploads\/sites\/79\/2021\/08\/Figure1_underwater_imaging_CIUS.png\"><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-15202 size-full\" src=\"http:\/\/blog.medisin.ntnu.no\/wp-content\/uploads\/2016\/12\/Figure1_underwater_imaging_CIUS.png\" alt=\"Graphs showing before and after nonlinear distortion.\" width=\"836\" height=\"597\" \/><\/a><figcaption id=\"caption-attachment-15202\" class=\"wp-caption-text\">Figure 1: Signal (top) and its frequency content (bottom) before (left) and after (right) nonlinear distortion. The frequency of the signal before distortion is 1 MHZ. It is a \u201cmonochromatic\u201d signal. After distortion, its frequency spectrum shows components around the upper harmonic frequencies: 2 MHz, 3 MHz, etc. The signal is now \u201cpolychromatic\u201d.<\/figcaption><\/figure>\n<p>In underwater acoustics however its applications seem to be reduced to the \u201cparametric arrays\u201d. These arrays usually quite large in size explore another effect nonlinearity that creates very directive sound at low frequency capable of penetrating deep into the ocean bottom. This type of sonars are most often used for &#8220;seeing beyond the ocean floor&#8221; also called sub-bottom profiling. There are today opportunities for using nonlinearity in applications such as seabed imaging or fish finding in ways similar to what is done in medicine with THI: second harmonic imaging in underwater acoustics.<\/p>\n<p>It is surprising that Thomas Muir who first thought about using nonlinearity in underwater acoustics imaging did not limit himself to the second harmonic but went all the way to image targets using the fifth harmonic when we know that the sound level decreases by at least 6 dB per harmonic.<\/p>\n<figure id=\"attachment_15203\" aria-describedby=\"caption-attachment-15203\" style=\"width: 507px\" class=\"wp-caption alignnone\"><a href=\"https:\/\/www.ntnu.no\/blogger\/cius\/wp-content\/uploads\/sites\/79\/2021\/08\/Figure2_underwater_imaging_CIUS.png\"><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-15203 size-full\" src=\"http:\/\/blog.medisin.ntnu.no\/wp-content\/uploads\/2016\/12\/Figure2_underwater_imaging_CIUS.png\" alt=\"Images from first trials of harmonic imaging in underwater acoustics.\" width=\"507\" height=\"536\" \/><\/a><figcaption id=\"caption-attachment-15203\" class=\"wp-caption-text\">Figure 2: First trials of harmonic imaging in underwater acoustics by Muir: \u201cNonlinear effects in acoustic imaging\u201d 1980. First five harmonics used to image a floating barge and a cylinder.<\/figcaption><\/figure>\n<p>I had the chance to meet Tom Muir recently at a conference. I told him that we were trying to take his pioneering work further and mentioned his article on harmonic imaging to which he replied \u201cthis paper was quickly forgotten\u201d but he was well aware that he tried harmonic imaging before it became widely spread in medical imaging.<\/p>\n<figure id=\"attachment_15204\" aria-describedby=\"caption-attachment-15204\" style=\"width: 225px\" class=\"wp-caption alignnone\"><a href=\"https:\/\/www.ntnu.no\/blogger\/cius\/wp-content\/uploads\/sites\/79\/2021\/08\/Figure3_underwater_imaging_CIUS-e1481882153185-225x300-1.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-15204 size-medium\" src=\"http:\/\/blog.medisin.ntnu.no\/wp-content\/uploads\/2016\/12\/Figure3_underwater_imaging_CIUS-e1481882153185-225x300.jpg\" alt=\"Fabrice Prieur and Tom Muir.\" width=\"225\" height=\"300\" \/><\/a><figcaption id=\"caption-attachment-15204\" class=\"wp-caption-text\">Figure 3: Thomas Muir (right) who pioneered the first trials on harmonic imaging in underwater acoustics.<\/figcaption><\/figure>\n<p>Only six years ago when we first started some experiments to prove the feasibility of second harmonic imaging using echo-sounders (simple sonars for fish finding) we were limited by the technology. The bandwidth (frequency range) of the system did not allow receiving the second harmonic and separate systems needed to be used for transmit and receive. Today the systems bandwidth has exploded going from 70 to 140 kHz or even from 200 kHz to 400 kHz making second harmonic imaging easily available.<\/p>\n<figure id=\"attachment_15200\" aria-describedby=\"caption-attachment-15200\" style=\"width: 300px\" class=\"wp-caption alignnone\"><a href=\"https:\/\/www.ntnu.no\/blogger\/cius\/wp-content\/uploads\/sites\/79\/2021\/08\/Figure4_underwater_imaging_CIUS.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-15200 size-full\" src=\"http:\/\/blog.medisin.ntnu.no\/wp-content\/uploads\/2016\/12\/Figure4_underwater_imaging_CIUS.jpg\" alt=\"EM2040 multi-beam echo-sounder from Kongsberg Maritime\" width=\"300\" height=\"166\" \/><\/a><figcaption id=\"caption-attachment-15200\" class=\"wp-caption-text\">Figure 4: EM2040 multi-beam echo-sounder manufactured by Kongsberg Maritime. (Image courtesy of Kongsberg Maritime)<\/figcaption><\/figure>\n<p>Using the second harmonic in addition to conventional imaging could not only improve the image quality but bring additional information about what we are imaging. Indeed when directing sound towards an object or an animal the level of sound reflected by it depends on the frequency of the incoming sound. Comparing the level of the sound received at the fundamental and second harmonic frequencies could help identifying targets.<\/p>\n<p>Gathering information contained in the echo of the fundamental frequency and of the upper harmonics would be a bit like switching from black and white to colour television. Preliminary tests on more advanced sonars used for bottom mapping (multi-beam sonars) using the second harmonic seem to be very promising. So let us turn the colours on!<\/p>\n","protected":false},"excerpt":{"rendered":"<p>When ultrasound propagates through water nonlinear effects come into play and distort the signal originally transmitted (Figure 1). The effect of this distortion can be seen as a transfer of energy around what is called \u201charmonic frequencies\u201d. For example if the signal originally transmitted has&#8230;<\/p>\n","protected":false},"author":433,"featured_media":18861,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[3],"tags":[116,117,54],"class_list":["post-15199","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-maritime","tag-acoustics","tag-harmonic-frequencies","tag-sonar"],"_links":{"self":[{"href":"https:\/\/www.ntnu.no\/blogger\/cius\/wp-json\/wp\/v2\/posts\/15199","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.ntnu.no\/blogger\/cius\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.ntnu.no\/blogger\/cius\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.ntnu.no\/blogger\/cius\/wp-json\/wp\/v2\/users\/433"}],"replies":[{"embeddable":true,"href":"https:\/\/www.ntnu.no\/blogger\/cius\/wp-json\/wp\/v2\/comments?post=15199"}],"version-history":[{"count":2,"href":"https:\/\/www.ntnu.no\/blogger\/cius\/wp-json\/wp\/v2\/posts\/15199\/revisions"}],"predecessor-version":[{"id":18864,"href":"https:\/\/www.ntnu.no\/blogger\/cius\/wp-json\/wp\/v2\/posts\/15199\/revisions\/18864"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.ntnu.no\/blogger\/cius\/wp-json\/wp\/v2\/media\/18861"}],"wp:attachment":[{"href":"https:\/\/www.ntnu.no\/blogger\/cius\/wp-json\/wp\/v2\/media?parent=15199"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.ntnu.no\/blogger\/cius\/wp-json\/wp\/v2\/categories?post=15199"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.ntnu.no\/blogger\/cius\/wp-json\/wp\/v2\/tags?post=15199"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}